Solar Battery Backup Calculator (2026)
Enter your AC tonnage, star rating, and backup hours needed — instantly get exact battery bank size, overnight AC sizing, and a comparison between LiFePO4 and Lead Acid options for Indian homes.
Overnight Sizing
8-Hr Power-Cut Mode
LiFePO4 + Lead Acid
Both Types Calculated
±10% Accuracy
BEE Load Data
Instant Results
No Login Needed
Real AC Load Calculation
Inverter ACs draw far less than rated wattage. We use BEE-based average consumption by tonnage and star rating — not peak nameplate values — for realistic backup estimates.
Overnight 8-Hr Sizing
Power cuts in India peak during 10 PM–6 AM in summer. We calculate exactly what battery bank keeps your AC running all night without grid power.
LiFePO4 vs Lead Acid
We size both battery types and show the full cost vs backup comparison — helping you decide whether the lithium premium is worth it for your use case.
Solar Battery Backup Calculator
Add your ACs below — results update live as you adjust.
Your Air Conditioners
1150W each · 1150W total
Your Battery Setup
Usable: 4.0 kWh at 80% DoD
Load Breakdown
Recommended Battery Banks
Based on your 1.15 kW load and 9.2 kWh overnight need
LiFePO4 5 kWh Bank
100Ah × 48V (1 battery)
- 80% usable depth
- Lightweight & compact
- 3000+ charge cycles
- No maintenance
LiFePO4 10 kWh Bank
200Ah × 48V (2 batteries in parallel)
- Full overnight for 2 ACs
- 80% usable DoD
- Solar rechargeable
- Stackable system
Lead Acid 7.2 kWh Bank
150Ah × 48V (4 batteries × 12V)
- Budget-friendly
- Easy local service
- Proven for inverters
- Widely available spares
Lead Acid 14.4 kWh Bank
300Ah × 48V (8 batteries × 12V)
- Maximum lead-acid capacity
- Handles 2–3 ACs overnight
- Robust for high loads
- Good cycle life if maintained
LiFePO4 vs Lead Acid — Which Should You Pick?
Quick Reference — Battery Need by AC Setup
Minimum battery installed capacity for 8-hour overnight backup
| AC Setup | Total Load | LiFePO4 Need (80% DoD) | Lead Acid Need (50% DoD) | 5kWh Battery | 10kWh Battery | Scenario |
|---|---|---|---|---|---|---|
| 0.75T 5★ Inverter, 1 AC | 650W | 6.5 kWh | 10.4 kWh | 6.2 hrs | 12.0 hrs | Small Room |
| 1T 5★ Inverter, 1 AC | 850W | 8.5 kWh | 13.6 kWh | 4.7 hrs | 9.4 hrs | Bedroom |
| 1.5T 5★ Inverter, 1 AC | 1150W | 11.5 kWh | 18.4 kWh | 3.5 hrs | 7.0 hrs | Most Popular |
| 1.5T 3★ Inverter, 1 AC | 1400W | 14.0 kWh | 22.4 kWh | 2.9 hrs | 5.7 hrs | Common |
| 2T 5★ Inverter, 1 AC | 1550W | 15.5 kWh | 24.8 kWh | 2.6 hrs | 5.2 hrs | Living Room |
| 1.5T 5★, 2 ACs | 2300W | 23.0 kWh | 36.8 kWh | 1.7 hrs | 3.5 hrs | 2-Room Home |
| 1.5T 5★, 3 ACs | 3450W | 34.5 kWh | 55.2 kWh | 1.2 hrs | 2.3 hrs | Large Home |
| 1T + 1.5T 5★ Mix, 2 ACs | 2000W | 20.0 kWh | 32.0 kWh | 2.0 hrs | 4.0 hrs | Typical Home |
Battery hours shown with LiFePO4 (80% DoD). Actual runtime varies with inverter efficiency (90–95%) and temperature. Add 15% buffer for real-world sizing.
Battery Backup FAQs
Everything you need to know about running ACs on battery in India
A 1.5T 5-star inverter AC draws ~1.15 kW on average. For 8 hours, you need 9.2 kWh of usable energy. With LiFePO4 (80% DoD), install 11.5 kWh. With lead acid (50% DoD), install 18.4 kWh. A 10 kWh LiFePO4 pack is the most practical choice for one 1.5T overnight.
Complete Your Solar + Battery Setup
Use these calculators together to plan your full off-grid system
4 Tools That Cut 200,000+ Indian Bills
These products are the most impactful bang-for-rupee upgrades based on our analysis. Combined annual savings: ₹2,400–₹4,800.

Tapo P110 16A Smart Plug
Monitor every appliance's power live
Real-time energy tracking per device
View on Amazon
Atomberg Renesa BLDC Fan
Runs on 28W — cuts fan bill by 65%
BEE 5-star · Remote control · Sleep mode
View on Amazon
V-Guard iMagno 410
Protect your AC from voltage surges
90–290V wide range · Auto reset · Delay
View on Amazon
HomeMate Smart IR Hub
Schedule any AC from your phone
Works with any IR AC · Alexa/Google
View on AmazonAmazon Associate Programme · We earn a small commission at no extra cost